As a member of Drucker's classic UNIK5000 family of pressure sensors, the UNIK5600 and 5700 series are DNV Classification Society certified and intrinsically safe. Classification Society certification means that the UNIK5600/5700 meets international standards, rules and regulations related to ships. Drucker silicon technology and analog circuits greatly improve accuracy, stability, low power consumption and frequency response performance. In addition, the excellent modular design

产品介绍/ Product introduction

High quality




● Drucker has more than 50 years of experience in pressure testing and measurement, and numerous field applications have witnessed the high quality and high stability of Drucker silicon core pressure sensor platforms.



Customization capability




● The modular design concept based on standard cells makes manufacturing the sensors you need simple and fast. This is equivalent to choosing one of the hundreds of thousands of UNIK5000 options tailored to your unique needs. Shorter lead times and more competitive prices give you peace of mind.



profession




● Drucker technicians with industry knowledge can meet your consulting needs for high-precision and high-reliability products. Our professional team can help you choose the right sensor, provide guidance and any other assistance you need.

peculiarity




● Range :70 mbar to 700 bar(depending on material)

● Accuracy up to ±0.04%FSBSL

● 316L stainless steel and titanium structure is optional

● Maximum frequency response 3.5kHz

● High overpressure ability

● Intrinsic safety and hazardous area certification

● 4-20 mA output

● Multiple pressure interface options

● DIN 43650 electrical connection or IP68 waterproof cable electrical connection

● Operating temperature :-40 to 80° C



Performance parameter




Measurement index


■ Pressure range


Gauge pressure range: optional between 0~7kPa and 0~7MPa

● Sealing gauge pressure range: optional between O~1MPa to 0~7OMPa (titanium structure up to 7MPa)

Absolute pressure range: optional between 0~10kPa and 0~70MPa (titanium structure up to 7MPa)

● Differential pressure range (stainless steel only)

Wet/dry unidirectional 7kPa~3.5MPa

The wet/dry bidirectional positive pressure end shall not exceed 3.5MPa, and the negative pressure end shall not exceed -1.5MPa. Please consult the sales representative for the specific optional range

Wet/wet unidirectional 35kPa~3.5MPa

The wet/wet bidirectional positive pressure end shall not exceed 3.5MPa, and the negative pressure end shall not exceed -1.5MPa. Please consult the sales representative for the specific optional range

Static pressure: up to 70 bar

● Atmospheric pressure range: The atmospheric pressure range can be selected from 350hPa to 1300hPa, and the minimum span is 350hPa

● Compound range: Compound pressure range is also available, including zero offset and negative pressure range and other non-zero range, if there is demand, please contact the sales representative


Maximum overpressure


● Range ≤15kPa: 10 × FS

● Range ≤35kPa: 4 ×FS

● Range ≤70kPa: 6×FS.

● Atmospheric pressure range :2×FS

● Other range :4×FS(range ≤7MPa, maximum 20MPa; Range >7MPa, maximum 120MPa)

● Differential pressure range, negative pressure port over positive pressure port shall not be greater than:

● Range ≤15kPa: 6×FS

● Range ≤70kPa: 4 ×FS

● Other measuring range :2×FS, up to 1.5MPa


The plugging pressure


Gauge pressure range ≤15kPa: 10×FS

Gauge pressure range ≤7MPa: 6 × FS(up to 20MPa)· Absolute pressure range<7MPa: up to 20MPa

● Measuring range >7MPa: up to 120MPa

● Differential pressure range: the negative pressure port cannot exceed 6×FS of the positive pressure port, up to 1.5MPa


■ supply voltage


● 7~32Vdc(Danger zone: 7~28Vdc)


output


●   4-20 mA


Indicates the power-on time


●   10ms


insulation


●   500 Vdc: 100 MQ

● 500 Vac: ≤5 mA leakage current


Performance index


● There are two accuracy levels to choose from: enhanced level and Superior level


Order accuracy


● Including nonlinear, hysteresis, repeatability effects

● Increase grade: ±0.1% FS BSL

● Excellent grade: ±0.04% FS BSL

● Note: For atmospheric pressure ranges, accuracy is calculated based on range span, not full scale


Order accuracy


● Including nonlinear, hysteresis, repeatability effects

● Increase grade: ±0.1% FS BSL

● Excellent grade: ±0.04% FS BSL

● Note: For atmospheric pressure ranges, accuracy is calculated based on range span, not full scale


Zero and full scale Settings


● DIN electrical interface allows to remove the electrical connection part, adjust the potentiometer, the adjustment amount is 5%(waterproof cable electrical interface is not provided). Factory Settings:

● DIN interface: 0.2%FS

● Waterproof cable interface: 1.0% FS

● Removable waterproof cable :±0.2% FS


Long-term stability


● Typical value: ±0.05%FS per year (Max. ±0.1% FS, with corresponding increases below 35kPa range)


Temperature effect


-10 ~ +50℃: ±0.5%FS Temperature error band (TEB)

● -20~+80℃: 1.0% FS TEB

●   -40~+80 ℃: ±1.5% FS TEB

● Measuring range below 35kPa, temperature influence increases correspondingly; Atmospheric pressure range temperature effect doubles


Static pressure effect (differential pressure only)


● Zero impact :< soil 0.03% range span /bar

● Full impact :< 0.03% range span /bar

● Measuring range below 70kPa, static pressure effect increases accordingly


Physical characteristics


Use environmental invitations


● See section on Electrical Interfaces. High pressure:

● Waterproof cable :20 bar

● Removable waterproof cable :10 bar


· Operating temperature range


● -40 ~80° C

● DNV certification temperature level :-25 ~ 70° C


Low pressure medium


● 316L Stainless Steel Option (5600) : For fluids compatible with 316L stainless steel and C276 Hastelloy For wet/dry differential pressure models, negative pressure port: Fluids compatible with 316L stainless steel, 304 stainless steel, pyro glass, silicon and structural adhesives

Metallic Titanium Option (5700) : Fluids compatible with titanium grades 2 and 4


Shell material


● Stainless steel or titanium (depending on housing material)

● DIN interface: glass filled nylon, rubber ring (nitrile material ○ ring and silicone liner)

● Waterproof cable interface :PTFE PTFE cone head, PVDF polyvinylidene fluoride cable


Pressure connection


● G1/4 internal thread. G1/4 external thread

● G1/2 external thread (via adapter)

● 1/4 NPT external thread

● 1/2 NPT external thread (via adapter)

● M20x1.5 external thread

● Input pressure joint (G1/4 internal thread opening)

For other pressure interface options, please contact Druck.


Wiring mode


Option code

Connection type

Electrical connection description

7

Type DIN 43650A

1

+ve Power supply

2

-ve Power Supply

3

-

E

shell

N

Waterproof cable

red

+ve Power supply

white

-ve Power Supply

P

Separable cable

red

+ve Power supply

white

-ve Power Supply

U

TPE-U waterproof cable

red

+ve Power supply

white

-ve Power Supply

V

Removable TPE-U waterproof cable

red

+ve Power supply

white

-ve Power Supply


Wiring mode


CODE

Description

Operating temperature range C

IP level

Zero-full regulation

7

DIN 43650 Type A

-40to +80

66

is

N

Waterproof cable

-40to +80

68

no

P

Separable cable

-40to +80

68

is

U

TPE-U waterproof cable

-40to +80

68

no

V

Waterproof cable

-40to +80

68

is


authentication


●   RoHS 2011/65/EU

●   Pressure equipment directive 2014/68/EU ATEX 2014/34/EU(optional)

●   EN 60079-0: 2012+A11: 2013

●   EN 60079-11: 2007

●   EN 50303:2000

●   EMC directive 2014/30/EUBS 

● EN 61000-6-1:2007 Anti-Interference - Light Industry

● BS EN 61000-6-2:2005 Anti-Interference - Heavy Industry

● BS EN 61000-6-3:2007 + A1:2011 Radiation - Light Industry

● BS EN 61000-6-4:2007+ A1:2011 Radiation - Heavy Industry

● BS EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use

● Ready -EMC requirements

● BSEN 61326-2-3:2013 Sensors for special requirements


Hazardous Area Certification (optional)


●   IECEx/ATEX Intrinsically Safe ‘ia’ Group llC

●   For full certification details, refer to the type-examinationcertificates (or approval listings) and Hazardous Arealnstallation Instructions.


Classification Society certification


Classification Society certification DNV: TAAO0000JY


●   IECEx/ATEX Intrinsically Safe ‘ia’ Group llC


Description

Lv.

temperature

D

humidness

B

Vibration

B

EMC

B

DIN plug waterproof cable 3 cable removable] Waterproof cable

C (IP56) D( (1P68 -200 mH,o) D (IP68 -100 mH,O)


Classification Society certification CCS: NJ16T00162


●   The pressure transmitteris suitable for use in the followingapplications:

●   1.Trim control

●   By moving fuel, cargo, and ballast around, the trim of theship is maintained

●   2.A ship can be considered as an industrial site with enginesand machines which have numerous pressure point measurement requirements.